Note the following when commissioning and switching on the Next Generation Hardware Appliance.
-
Make sure that the seal on the right-hand side of the Hardware Appliance is intact and has not been tampered with.
-
Make sure that the power supply units are seated correctly.
-
Connect both power cables.
-
Connect both network cables.
Both network cables must be plugged in and connected to the network before the Hardware Appliance is started.
For u.trust SE100/SE2K
-
Insert a battery into the External Battery Adapter and connect it.
The External Battery Adapter should already be equipped with a battery and operational even the Hardware Appliance is not installed immediately upon delivery.
Important!
It is important that the External Battery Adapter is constantly in use.
-
Connect the PIN pad smart card reader to the Hardware Appliance.
-
Switch on the device to start booting. Booting will take about 5 minutes.
For Luna S790
-
Connect the PED to the Hardware Appliance or continue setting up the remote PED later.
-
Switch on the device to start booting. Booting will take about 5 minutes.
IP address
-
To set the IP Address follow, the instructions on the display on front of the device. See Getting Started for more information.