The Overview page provides all relevant data on the Keyfactor Next Generation EJBCA Hardware Appliance.
In the top row you will find all the tabs with which you can open and operate the sub menus.
The current system date and UTC time are displayed further to the right in the same line.
Hardware Overview
Here you will find all the information about the appliance hardware:
The current Hardware Version
CPU Temperature (displayed in Fahrenheit or Celsius).
Hover the mouse over the value to switch between the display in [F] or [C].
The CPU Temperature should not exceed 84°C/183°F.Memory Usage (displayed in % and GiB)
Disk in Slot 0 (should state: RAID disk present and synced)
Disk in Slot 1 (should state: RAID disk present and synced)
RAID state (should state: Normal)
Service Overview
Here you will find all the information about:
SNMP (default OFF)
Syslog (default OFF)
Backup (default OFF)
HTTP EJBCA (should be ON)
HTTPS EJBCA, Webconf (should be ON)
VPN (should be ON, only displayed while clustering)
Click Configure Services to to go straight to the Services page.
HSM Overview
Here you will find all the information about:
Status (should be RUNNING when initialized)
Operating Mode (should be OPERATIONAL)
HSM Firmware (current version should be displayed)
Temperature (displayed in Fahrenheit or Celsius). Hover the mouse over the value to switch between [F] or [C]. Values for the temperature sensors that trigger a manipulation reaction if the module is outside the defined temperature range of are:
–18°C to 81°C (-0.4°F to 177.8°F).Carrier Battery (displayed in V)
External Battery (displayed in V)
Alarm (should be OFF when initialized)
Click Configure HSM to go straight to the Security page.
Database Overview
Here you will find all the information about:
Status (should be CONNECTED)
Type (is Internal Database)
Disk Usage (displayed in % and TiB)
Remaining Disk Space (displayed in TiB)
Click Configure Database to go straight to the Applications page.
Application Overview
Here you will find all the information about:
EJBCA and the current version number.
the button to enter the Admin Web or if applicable Maintenance is displayed.
if no HSM is initialized, the message RESTARTING is displayed instead of the Admin Web button.
Recent Activity
Here you will find all the information about the recent activity. The last 10 entries are displayed. There is no limit to the number of entries.
Click < Previous or Next > to move back and forth between the different pages.
Device Overview
Here you will find all the information about the connected device(s), for example a connected PIN pad.