Luna S790

The following covers how to configure a Luna S790 HSM for the Next Generation Hardware Appliance.

Security Transport Mode (STM)

The HSM is secured during transportation. When initializing the HSM for the first time, the STM must have been removed. To do so, a Random User String and a Verification String were sent by Keyfactor via email upon delivery. These strings must be used in Webconf to remove the appliance from STM.
For more information refer to Secure Transport Mode (STM).

Preparations

The PIN Entry Device (PED) was delivered with the appliance, including 10 PED keys and a sheet with labeled peel-off stickers for the PED keys. It is recommended that the PED keys to be used are provided with the corresponding stickers in advance.

Before starting, the PED must have been configured via Webconf.

For more information, refer to PIN Entry Device.

HSM Information

The appliance is still in Secure Transport Mode and no HSM has yet been initialized.
The last three lines adapt to the respective status.

Name

Value

Serial Number

xxxxxx

Firmware

e.g. 7.8.4

Fan 1

active

Fan 2

active

Battery

e.g. 3.098 V

Temperature

in °C e.g. 31 deg. C

(warning) Alarm

ON/OFF

Status

transport_mode (while in Secure Transport Mode (STM))
zeroized (when exited STM and not initialized)
RUNNING (when initialized)

(warning) Secure Transport Mode

ON/OFF

If an (warning) Alarm has been triggered, a message with further explanations is displayed in a banner at the top of the Security page.

For more information, refer to the Thales documentation Luna S790 HSM Documentation.

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.